Tennessee · answered by Verika · verified against sources

What air content is required for concrete on Tennessee DOT projects?

"Design Class D , Class DS, and Class L concrete at 7% air content . Acceptance range for pumping and other methods of placement is 4.5 - 7.5%. Sampling will be at the truck chute." [2] "Class of Concrete Min 28 - Day Compressive Strength (psi) Min Cement Content (pound per cubic yard) Maximum Water/Cement Ratio (pound/pound) Air Content % (Design + production tolerance) Slump (inches) A 3,000 564 0.45 6 + 2 3 + 1" [2] "D, DS (2, 3) 4,000 620 0.40 7 (3) 8 max (4)" [2] "air entrained and produce a workable concrete mix meeting the design and production parameters specified in Table 501.03 - 1." [3]

Every answer carries its source — tap a citation to read the official document.

This answer came from Verika — an expert in your pocket. Ask anything, out loud or typed; answers come from your region’s regulations and your team’s own knowledge, cited to the source. If it isn’t in the sources, Verika says so.

Verika provides information with citations to help you find and understand the rules that apply to your work. It is not a substitute for professional engineering or legal judgment. Answer generated 2026-08-28; always confirm against the cited source for your project.