Cold weather is defined as ambient air temperature <35°F [2°C] measured 5 ft [1.5 m] above ground in shade. Remove snow/ice/frost from surfaces contacting concrete; ensure contact surfaces ≥35°F [2°C]. Use heaters gradually to avoid surface temps >90°F [32°C] before setting; vent exhaust gases outside. Protect concrete for ≥7 days so surface temp doesn’t drop below 50°F [10°C]; extend to 10 days if fly ash/slag/silica fume are used. Avoid direct flame heating of aggregates or direct steam for fine aggregate; no salts for freezing prevention.